Supplies Online | Chromatography Parts and Services | Worldwide Shipping
(+30) 2310634682 | This email address is being protected from spambots. You need JavaScript enabled to view it.
GC Parts and Accessories
Accessories
Nuts and ferrules
GC Columns
Filters and Purifiers
Autosampler parts
Agilent
Syringes and Needles
Vials and caps
Perkin Elmer
Syringes and Needles
Vials and caps
Shimadzu
Syringes and Needles
Vials and caps
Thermofisher
Syringes and Needles
Vials and caps
Detector parts
Agilent
Perkin Elmer
Shimadzu
ThermoFisher
Injector parts
Agilent
Liners
Septa
Perkin Elmer
Liners
Septa
Shimadzu
Liners
Septa
ThermoFisher
Liners
Septa
LC Parts and Accessories
Accessories
Nuts and Ferulles
LC Columns
Tubing and Fittings
Autosampler Parts
Agilent
Vials and caps
Injector valve accessories
Syringes and Needles
Dionex
Vials and caps
Injector valve accessories
Syringes and Needles
Gilson
Vials and caps
Injector valve accessories
Syringes and Needles
Shimadzu
Vials and caps
Injector valve accessories
Syringes and Needles
ThermoFisher
Vials and caps
Injector valve accessories
Syringes and Needles
Waters
Vials and caps
Injector valve accessories
Syringes and Needles
Detector Parts
Agilent
Lamps
Flow Cells
Dionex
Lamps
Flow Cells
Gilson
Lamps
Flow Cells
Shimadzu
Lamps
Flow Cells
ThermoFisher
Lamps
Flow Cells
Waters
Lamps
Flow Cells
Pump Parts
Agilent
Check Valves
Seals
Pistons
Dionex
Check Valves
Seals
Pistons
Gilson
Check Valves
Seals
Pistons
Shimadzu
Check Valves
Pistons
Seals
ThermoFisher
Seals
Piston
Check Valves
Waters
Check Valves
Seals
Pistons
Mass Spectrometer Parts
Filaments
Agilent
Shimadzu
Perkin Elmer
Thermofisher
Heaters
Agilent
Shimadzu
Perkin Elmer
Thermofisher
Multipliers
Agilent
Shimadzu
Perkin Elmer
Thermofisher
ICP Parts
Accessories
Nebulizers
Agilent
Perkin Elmer
Shimadzu
Thermofisher
Torches
Agilent
Perkin Elmer
Shimadzu
Thermofisher
Vacuum Parts
Fittings
Oil
Rebuild kits (Blades, Gaskets,O'rings)
Alcatel
Becker
Busch
Edwards
Leybold
Pfeifer
Rietchle
Varian
Atomic Absorption Parts
Perkin Elmer
Shimadzu
Thermofisher
Varian
Lab Equipment
Cabinets
Flocculators
Hot Plates
Immersion Thermostats
Incubators
Magnetic Stirrers
Vacuum pumps
Refrigerated Baths
Balances
Shakers & Mixers
Special Baths
Thermostatizated Baths
Ultrasonic Bath
Dissolution Accessories
Misc
Vessels
Filters
Used Equipment

Shopping Cart

 x 
Cart empty

Log in

Login to your account

Username *
Password *
Remember Me

Used Micromass LCT TOF Mass Spectrometer

Email
Used Micromass LCT TOF Mass Spectrometer
micro
Description

A used fully refurbished & serviced Micromass LCT TOF Mass Spectrometer. Including installation, training and 3 months warranty. MS Workstation (with built in noise reduction) and Waters 2695 Alliance HPLC available at additional costs, please contact us for details. Service contracts also available.

 

Ionisation Techniques

Using the Micromass Z-spray atmospheric pressure ionisation (API) source, two techniques are available. 

Atmospheric Pressure Chemical Ionisation

Atmospheric pressure chemical ionisation (APcI) generally produces protonated or deprotonated molecular ions from the sample via a proton transfer (positive ions) or proton abstraction (negative ions) mechanism. The sample is vaporised in a heated nebuliser before emerging into a plasma consisting of solvent ions formed within the atmospheric source by a corona discharge. Proton transfer or abstraction then takes place between the solvent ions and the sample. Eluent flows up to 2 millilitres/minute can be accommodated without splitting the flow.

 Electrospray

 

Electrospray ionisation (ESI) takes place as a result of imparting a strong electrical charge to the eluent as it emerges from the nebuliser. An aerosol of charged droplets emerges from the nebuliser. These undergo a reduction in size by solvent evaporation until they have attained a sufficient charge density to allow sample ions to be ejected from the surface of the droplet (“ion evaporation”).

 A characteristic of ESI spectra is that ions may be singly or multiply charged. Since the mass spectrometer filters ions according to their mass-to-charge ratio (m), compounds of high molecular weight can be determined if multiply charged ions are formed.

 

 

 Eluent flows up to 1 ml/min can be accommodated although it is often preferable with ionisation to split the flow such that 100 to 200 µl/min of eluent enters the mass spectrometer.

 

 Nanoflow Electrospray

 

The optional nanoflow interface allows electrospray ionisation to be performed in the flow rate range 5 to 1000 nanolitres per minute.

 For a given sample concentration, the ion currents observed in nanoflow are comparable to those seen in normal flow rate electrospray. Great sensitivity gains are therefore observed when similar scan parameters are used, due to the great reductions in sample consumption.

 

 Ion Optics

 

The principle components of the ion optical system are shown here in schematic form. Ions generated in the Z-spray source are transferred to the orthogonal time of flight analyser via the two independently pumped RF lenses. After entering the analyser the ion beam is focused into the pusher by the acceleration, focus, steer and tube lenses. The pusher then pulses a section of the beam towards the reflectron, which then reflects ions back to the detector. As ions travel from the pusher to the detector they are separated in mass according to their flight times, with ions of the highest mass to charge ratio (m) arriving later in the spectrum.

 The pusher may be operated at repetition frequencies of up to 20 kHz, resulting in a full spectrum being recorded by the detector every 50 microseconds. Each spectrum is summed in the histogram memory of the time to digital converter until the histogrammed spectra is transferred to the host PC.

 

 If the user has requested an acquisition rate of 1 spectrum/second, each spectrum viewed on the host PC will be the result of summing up to 20,000 individual spectra recorded at the detector.

 

 Unlike scanning instruments, the TOF performs parallel detection of all masses within the spectrum at very high sensitivity and acquisition rates. This characteristic is of particular advantage when the instrument is coupled to fast chromatography, since each spectrum is representative of the sample composition at that point in time, irrespective of how rapidly the sample composition is changing.

 

Chromatography Spares
5 Salaminos Str
54626, Thessaloniki
Greece
Tel: (+30) 2310634682
Mob: (+30) 6977127557
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.